PRELIMINARY OPERATIONS
- Connect the vacuum cleaner's power supply cable plug to a suitable socket;
- Connect the pump's plug D to the outlet C situated on the head of the vacuum cleaner;
- Connect the water drain pipe from the drum to fitting 1;
- Connect the suction accessories to the inlet of the tank F.
WET SUCTION
- When all the parts are assembled as indicated above, start the vacuum motors by
pressing switches B. Vacuum the liquids using the accessories supplied
- During tank F filling the float U rises;
- When it reaches the trigger level, it activates the pump to empty the tank;
- When the tank is emptied, the float goes down again to the bottom level and the pump
stops automatically;
- The pump's trigger level (pre-set on assembly) can be changed from the cable length
of the float that comes out from cable retainer T.
DRY SUCTION
- So as not to damage the emptying pump when vacuuming solids, it is required to
remove it before starting any work;
- To remove the pump, loosen the ring nut of fitting 5 situated on the pump and remove
plug D after removing ring nut Y
- Extract the pump from tank F, then assemble cap Z instead of ring nut Y;
- For dry suction it is required to insert filter K into the drum. This, as well as the cap, is
not a standard supply. If your vacuum is equipped with paper bag L, slide paper bag
over the deflector.
ENGLISH
15