OPTIONALS -
For the connections and the technical data of the fixtures follow the relevant handbooks.
RADIO TRANSMITTER SUN
SUN 2CH
code ACG6052
SUN CLONE 2CH
code ACG6056
CODE LEARNIG SYSTEM RADIORECEIVERS
S433 1CH
1-channel with plug
S433 1CH
1-channel with terminal block
S433 2CH
2-channels with plug
S433 2CH
2-channels and terminal block
S433 4CH
4-channels with plug
S433 4CH
4-channels and terminal block
SPARK
In order to make the systems mentioned above give the best performances, you need to
install an antenna tuned on the frequency of the radio receiver installed.
N.B. Pay attention to not let the central wire of the cable to came Into contact
with the external copper sheath, since this would prevent the antenna from
working.
Install the antenna vertically and in such a way the remote control can reach it.
SPARK BLINKER WITH IN-BUILT INTERMITTENT CARD
LATERAL SUPPORT
SPARK ANTENNA 433
PUSH-BUTTON FLAT
SUN 4CH
code ACG6054
SUN CLONE 4CH
code ACG6058
code ACG5081
code ACG5082
code ACG5083
code ACG5084
code ACG5085
code ACG5086
code ACG7059
code ACG7042
code ACG5452
code ACG2013
FIT SLIM
PHOTOCELLS for the wall-installation
PAIR OF COLUMNS FOR FIT SLIM
FIT SLIM photocells have synchronism function in AC current and ranges of 20 m.
You can fit many photocell couples close together thanks to the optional synchronizing
circuit SYNCRO TRANSMITTER TX SLIM SYNCRO
for more than 2 photocells couples (up to 4).
BLOCK
KEY SELECTOR FOR WALL-INSTALLATION
KEY SELECTOR TO BUILD-IN
HEATER ONLY FOR KING ICE
The in-built thermal sensor of the KING ICE motor can be connected to the terminal
block J7 on the T2 control board. For the connection details please refer to the KING ICE
Instruction Manual.
The probe for motor heating is a device intended to be used in extremely cold environment
(up to -30°C) to avoid motor freezing.
Such device activates automatically when the gate is steady (the position being irrelevant,
provided it is not moving) at a ambient temperature motor inferior to 10°C (found from the
sensor of temperature PROBE).
The work of the heater is indicated by both the DL6 and DL7 leds for the motor number
1, and by the DL4 and DL5 leds for the motor number 2.
When the motor is running the heating system is inoperative.
On elapsing of 10 seconds delay from gate stop, the heating system gets activated (in
case the environment temperature in the motor area is below 10°C).
Upon achieving a 20°C temperature the heating system deactivates, maintaining a
constant environment temperature.
TECHNICAL DATA
Operation voltage
5Vdc
Resistance
10K ±2% (at 25°C)
Working temperature
-30 ÷ +55°C
27
G
B
code ACG8032
code ACG8065
code ACG8029
code ACG1053
code ACG1048