6.2.22.1 Example of Patrol sequence
programming.
If you want to set up a Patrol sequence that starts
from Preset position 19, ends at Preset position 33
and stops for one minute at every position reached:
: Enables parameter insertion;
  
: Start Patrol at position 19;
  
: End Patrol at position 33;
  
: Pause of 60 seconds at every position
  
reached;
: Start of sequence;
  
: End of sequence.
  

6.2.23 Switching on and switching off

Before connecting the unit:
• Make sure that the goods supplied correspond
to the required specifications by controlling the
rating plates ("4.2 Product markings", page 7);
• Make sure that the fuses of the EXDTRX3 /
EXDTRX324 receiver are not damaged;
• Make sure that the receiver and the other
components of the plant are closed in order to
avoid the direct contact with live elements;
• Make sure that all parts are accurately and firmly
fixed;
• The power cords must not hamper the normal
operations of the installer and the movement of
the positioning device;
• Make sure that all power sources and the
connecting cables are able to bear the system
consumption.
18
6.2.24 Dip switch SW6 and SW4
configuration table
SW6
Dip
Position
1
ON
1
OFF
2, 3, 4
Indifferent
SW4
Dip
Position
1, 2
OFF, OFF
1, 2
ON, OFF
1, 2
OFF, ON
1, 2
ON, ON
3
OFF
3
ON
4
OFF
4
ON
5
OFF
5
ON
6
OFF
6
ON
7
OFF
8
ON**
8
OFF***
Tab. 04
* Default settings.
** Compatible with keyboards DCIR, DCJ, DCT and
DCTEL with VIDEOTEC standard protocol.
*** Compatible with keyboards DCIR, DCJ, DCT and
DCTEL with MACRO protocol.
**** Selectable only if the dip 1 of SW6 is in OFF
position.
Function
PELCO D protocol
VIDEOTEC or MACRO
protocols (setting the dip 8
of SW4)
No function
Function
9600 baud* (VIDEOTEC and
MACRO), 2400 PELCO D
300 baud VIDEOTEC, 38400
baud MACRO, 4800 baud
PELCO D
1200 baud (VIDEOTEC and
MACRO), 9600 baud PELCO D
19200 baud (VIDEOTEC,
MACRO and PELCO D)
Unused alarms*
Used alarms
N.C. alarms*
N.O. alarms
-
Alarms on Aux4
-
To release Aux3 and Aux4
-
VIDEOTEC standard
protocol****
MACRO protocol **** ((DCIR,
DCJ, DCT and DCTEL)