SYSTEM CHECKS

1. Conceal the tubing where possible.
2. Make sure that the drain tube slopes downward along its entire length.
3. Ensure all tubing and connections are properly insulated.
4. Fasten tubes to the outside wall, when possible.
5. Seal the hole through which the cables and tubing pass.
Indoor Unit
1. Do all remote control buttons function properly?
2. Do the display panel lights work properly?
3. Does the air deflection louver function properly?
4. Does the drain work?

TROUBLESHOOTING

For ease of service, the systems are equipped with diagnostic code display LEDs on both the indoor and outdoor units. The indoor diagnostic display is
a combination of flashing LEDs on the display panel or the front of the unit.
Some indoor units display error codes specifying failure modes in outdoor units. If possible, always check the diagnostic codes displayed on the indoor
unit first.
The diagnostic codes displayed in the indoor and outdoor units are listed in the Table 8.
INDOOR UNIT DIAGNOSTIC GUIDES
OPERATION LAMP
TIMER LAMP
1 time
2 times
3 times
4 times
5 times
5 times
5 times
5 time
5 times
6 times
6 times
12 times
9 times
8 times
7 times
2 times
3 times
5 times
1 time
6 times
7 times
1 time
9 times
11 times
© 2021 Carrier. All rights reserved.
A Carrier Company
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 8 — Indoor Unit Diagnostic Guides
DISPLAY
EH00/EH0A
X
EL01
X
EH02
X
EH03
X
EC51
X
EC52
X
EC53
X
EC54
X
EC56
X
EH60
X
Eh61
X
EC07
X
EH0b
X
EL0C
X
PC00
«
PC01
«
PC02
«
PC04
«
PC08
«
PC40
«
PC03
«
--
O
EHb1
X
FH0d
X
O (light) X (off) «(flash)
Edition Date: 06/21
Explain Following Items To Customer (with the aid of the Owner's
Manual):
1. How to turn air conditioner on and off; selecting COOLING,
HEATING and other operating modes; setting a desired temperature;
setting the timer to automatically start and stop air conditioner
operation; and all other features of the remote control and display
panel.
2. How to remove and clean the air filter.
3. How to set air deflection louver.
4. Explain care and maintenance.
5. Present the Owner's Manual and installation instructions to customer.
Indoor unit EEPROM parameter error
Indoor / outdoor units communication error
Zero-crossing signal detection error
Indoor fan operating outside of the normal range
Outdoor unit EEPROM parameter error
T3 is in open circuit or has short circuited
T4 is in open circuit or has short circuited
TP is in open circuit or has short circuited
T2B is in open circuit or has short circuited
T1 is in open circuit or has short circuited
T2 is in open circuit or has short circuited
Outdoor fan operating outside of the normal range
Indoor PCB/Display board communication error
Refrigerant leakage detection
IPM malfunction or IGBT OSCP
Over voltage or over low voltage protection
Compressor or IPM high temp/pressure protection
Inverter compressor drive error
Current overload protection
Comm. error between outdoor chip and compressor chip
Low pressure protection
Indoor units mode conflict
Indoor board and Multi-function communication error
Ionizer malfunction