12 Set-up / operation

► After mounting, wiring and programming check whether the unit operates correctly�
> If the unit has been correctly set up, the distance to the object is indicated�
Lifetime of a laser diode: 50000 hours
12.1 Fault indication
Possible
cause
too much
light,
[++]
e�g� reflective
surface
too little light,
[- -]
no object
object to be
measured
[nEAr]
outside the
measuring
range < 0�2 m
object to be
measured
[FAr]
outside the
measuring
range > 3�5 m
plausibility
[Errp]
(e�g� object
too fast)
[SC1]
short circuit in switching output 1
[SC2]
short circuit in switching output 2
[SC]
short circuit in all switching outputs
unchanged
1)
[SC1] or [SC] only active, if output 2 is configured as switching output�
2)
See IODD of the device
3)
54
Switching output
[Hno] [Hnc] [Fno] [Fnc]
ON OFF OFF ON
OFF ON OFF ON
ON OFF OFF ON
OFF ON OFF ON
X
X
X
X
1)
1)
1)
1)
Current output /
voltage output
[ASP] < [AEP]
[ASP] > [AEP]
3,5 mA / 0 V
20,5 mA / 10 V
20,5 mA / 10 V
3,5 mA / 0 V
3,5 mA / 0 V
20,5 mA / 10 V
20,5 mA / 10 V
3,5 mA / 0 V
X
1)
2)
2)
X
1)
2)
2)