10�2�4 Hysteresis Function - Autosen AL001 Notice D'utilisation

Détecteur de distance optique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.2.4 Hysteresis function
The hysteresis keeps the switching state of the output stable if the measured
value varies about the sensing range� In either case set and reset points are
symmetrically arranged around the selected switch point [SPx]� The hysteresis
is the distance between set and reset points; it is calculated on the basis of
the repeatability with a safety factor of 1�5� The calculation is based on the
repeatability for max. 40 klux. → 10.3.3 Table repeatability and accuracy
Example Hno
1� For the output function [Hno] the output switches when the object approaches
and when the switch point (A) is reached�
2� When the object is removed again, the output does not switch back before the
reset point (B) is exceeded�
The reset point (B) is greater than the set point (A)�
1
2
[SPx] = switch point; A = set point; B = reset point
When the output function [Hnc] was selected, set and reset point are reversed�
The output is switched off when the object approaches� When the object is re-
moved, the output switches on�