2.10 Technical Data
Nominal size:
Accuracy class 0.5
Display:
Measuring range:
Overload range 30.08.01
Power supply:
Service-life at conversion rate 5/s:
Conversion rate:
Automatic switch-off times:
(auto off )
Zero point correction:
Parts in contact with medium:
Connection:
Medium temperature:
Ambient temperature:
Storage temperature:
Permissible relative humidity:
P P r r o o t t e e c c t t i i o o n n c c a a t t . . : :
Limit-value relay (Option):
M M a a x x . . s s w w i i t t c c h h i i n n g g p p o o w w e e r r : :
Analogue output (Option):
L L o o a a d d : :
Peak value memory (Option):

2.11 Dimensions

Rotating
display
74 mm
0.5
4-digit LCD; digit height 12.7 mm
-1...0, 0...1, 0 - 1.6, 0 - 2.5, 0...4, 0...6, 0...10, 0...16,
0...25, 0...40, 0...60, 0...100, 0...160, 0...250, 0...400
3 x PN (upto 40 bar)
2 x PN (60 bis 250 bar)
1,5 x PN (ab 250 bar)
9 VDC (block battery)
5000 h (block battery 600mAh),
10000 h (Lithium blockbattery 1200 mAh)
5 per Sec. (standard)
(1 to 10 per sec. Factory-adjusted)
2 ...... 90 min, Only factory-adjustable.
0 = inactive (not recommended with analogue or switching output)
25 %
St.Steel 1.4571, Ceramic, NBR
1
1
G
/
(Manometer),
/
" NPT (Option)
4
4
-30...+85°C
0...+60°C
-30...+80°C
90%, not condensing
IP 65
N.O., bistable
arbitrary adjustable, adjustable hysteresis
30 V AC/DC, 2 A
0 - 2 VDC
100k
Min or Max value, Resetting via keypad
Optional: PG7 (LCD)
GB