NO HEAT
1. Dirty filter: Clean the filter per the instructions provided in the Maintenance
section of this manual. The filter should be replaced every two months. If the filter
is more than two months old, replace it. After cleaning or replacing the filter, cover
the spa, turn the temperature set point to 'High', and leave the spa for 24 hours. If
the spa still will not heat, contact the manufacturer for instructions.
2. No circulation, water pump is air bound: Unplug the Main Power Unit from the
electrical outlet. Bleed air from the filter tank by turning the bleed fitting on the top
of the filter tank counter-clockwise. After one minute, or when water drips from the
fitting, close the bleed fitting and plug in. Make sure that the filter pump inlet and
outlet, located on the inner side wall of the spa, are opened by turning the nozzles
counter-clockwise and on some models, remove the outlet valve cover as well.
And if the water pump becomes air bound again, check the Pump / Filter Cover
Seal on the top of the filter tank. Refer to the filter changing instructions in the
Maintenance section of this manual. Replace the Pump / Filter Cover Seal if
necessary. If the water pump still does not pump water, contact the manufacturer
for instructions.
3. Faulty Main Power Unit: Ensure power is available to the spa. Check the circuit
breaker at the main electrical panel. Connect another electrical appliance to the
plug used for the spa. If power is available to the spa, test the GFCI using the
instructions supplied in the Maintenance section. If the GFCI is working properly
and the Main Power Unit does not function, the Main Power Unit is defective. If the
GFCI is not working properly, do not use the spa. Contact the manufacturer
immediately for instructions.
4. Thermostat Malfunction: A thermostat malfunction will cause the heating coil in
the filter/pump unit to overheat, at which time it will automatically shut down until it
cools off. If the internal thermostat malfunctions, the three heat level lights on the
pump/filter control panel will start to flash simultaneously. The lights will continue
to flash until the heating coil has cooled down enough to be turned back on. Once
the lights stop flashing, press the manual reset button on the side of the pump/filter
unit. Next, press the FILTER ON button, followed by the HEAT ON/LEVEL button on
the pump/filter control panel. This will manually reset the thermostat and allow you
to continue normal use.
LEAKS:
1. Blower connection is leaking: If the blower connection between the spa and the
Main Power Unit is leaking, ensure the Adapter A Seal inside the fitting is in place
and undamaged.
2. The water inlet / outlet connections between the Main Power Unit and the spa
are leaking: Ensure the Adapter B and C Seal inside each of these fittings is still in
place and undamaged.
3. Water drain valve is leaking: Make sure valve is turned off, by turning clockwise
and ensure the o-ring inside the fitting is in place and undamaged.
15