How the electronic
First, large particles (lint, hair) are caught by the
air cleaner works
prefilter(s). Then, as the dirty air passes through
the intense high voltage electric field surround-
ing the ionizer wires, all particles, even the
smallest are given an electric charge. The air
then passes into the collector where the
alternate parallel plates are charged positive
and negative, creating a uniform electrostatic
field. Since opposites attract, the charged
particles stick to the collector plates, which have
an opposite electric charge. The air leaving the
air cleaner contains very few particles.