Layering
As in the direct build-up method described on pages 18–20 . Do not use protective varnish!
Curing
lt is advisable to cure in a pressure vessel for 10 minutes at 40–50 °C, 1,4–4 bar .
For large or complicated workpieces an intermediate cure of the applied material is
recommended, also of 10 minutes at 40– 50 °C, in the pressure vessel .
Fig . 12