Technical data
Optical data
Measuring range
Measuring laser
Diameter of light spot
Repeatability
Linearity
Pilot laser
Switching points
Switching hysteresis
Electrical data
Operating voltage
Residual ripple
Current consumption
Outputs Q1/Q2
Protection class
Short-circuit protection/polarity
reversal protection
Analogue output
Mechanical data
Casing material
Protection standard
Ambient temperature range
Plug connection
Accessories
Cable
Mounting component
Refl ector
Wiring diagram
1
BN
+UB
5
GY
4 BK
2
mA
WH
Q
A
Q
3
BU
B
-UB
FT 92 ILA
0.2 ... 6 m (grey 18 %)
IR 900 nm, laser protection class 1
5 x 10 mm @ 3 m
± 10 mm / ± 15 mm (depending on
mode of operation)
± 40 mm
Red 650 nm, laser protection class 2
Freely adjustable(Teach-in)
30 mm (fi xed)
18 ... 30 V DC integrated polarity
reversal protection
10 % within Ub
< 3 W at 25° C
PNP, 100 mA
Yes (all outputs)/Yes
4 ... 20 mA
ABS shock-resistant
IP67
-10 ... +50 °C
Plug M12 5-pin
5-pin standard M12 cable , e.g. L5-2m-
W-PUR (Art. 902-51613)
Dimensional drawing
42
SensoPart Industriesensorik GmbH
Tel. +49 (0) 7673 821-0, Fax +49 (0) 7673 821-765
E-Mail: info@sensopart.com
www.sensopart.com
0.2 ... 30 m (refl ector RL250)
IR 900 nm, laser protection class 1
15 x 20 mm @ 10 m
± 5 mm / ± 10 mm (depending on
mode of operation)
Red 650 nm, laser protection class 2
Freely adjustable(Teach-in)
30 mm (fi xed)
18 ... 30 V DC integrated polarity
reversal protection
10 % within Ub
< 3 W at 25° C
PNP, 100 mA
Yes (all outputs)/Yes
ABS shock-resistant
-10 ... +50 °C
Plug M12 5-pin
5-pin standard M12 cable , e.g. L5-
2m-W-PUR (Art. 902-51613)
e.g. MSP F90 (Art. 599-91002)
e.g. RL 250 (Art. 904-51578)
12.3
94.39
42
43
FR 92 ILA
± 60 mm
4 ... 20 mA
IP67

Publicité