Other Storage Instructions; Transporting/Tipping Of The Unit - Generac CW15 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance
There is no need to drain gasoline from the engine if a
fuel stabilizer is added according to instructions. Run the
engine for 2 minutes to circulate the stabilizer throughout
the fuel system. The engine and fuel can then be stored
up to 24 months.
If gasoline in the engine has not been treated with a fuel
stabilizer, it must be drained into an approved container.
Run the engine until it stops from lack of fuel. The use of
a fuel stabilizer in the storage container is recommended
to maintain freshness.
Hearing Protection Recommended.
6.12.2 — Protect Engine
1. Change engine oil.
2. Remove spark plug.
3. Pour a tablespoon (5-10 cc) of clean engine oil into
the cylinder.
4. Pull the starter rope several times to distribute the oil
in the cylinder.
5. Reinstall the spark plug.
6. Pull the starter rope slowly until resistance is felt.
This will close the valves so moisture cannot enter
the engine cylinder. Return the starter rope gently.
6.12.3 — Change Oil
Allow the engine to cool down and then drain oil from
crankcase. Refill with recommended grade. See "Chang-
ing Engine Oil".
Hot oil may cause burns. Allow engine to cool
before draining oil. Avoid prolonged or
repeated skin exposure with used oil. Thor-
oughly wash exposed areas with soap.
6.12.4 — Protecting the Pump
To protect the pump from damage caused by mineral
deposits or freezing. Make sure the pump is completely
drained of all water. Spray WD-40, or similar product, into
all ports and drainage hole.
• Failure to do so will permanently damage your pump
and render your unit inoperable.
• Freeze damage is not covered under warranty.
Water Pump
6.13 — O
S
THER
TORAGE
1. DO NOT store fuel from one season to another
unless it has been treated as described in Protect
Fuel System.
2. Replace fuel container if it starts to rust. Rust and/or
dirt in fuel can cause problems if it's used with this
unit.
3. Cover unit with a suitable protective cover that does
not retain moisture.
Storage covers can be flammable.
• DO NOT place a storage cover over a hot water pump.
• Let equipment cool for a sufficient time before placing
the cover on the equipment.
4. Store unit in a clean and dry area.
6.14 — T
RANSPORTING
U
NIT
Do not operate, store or transport the unit at an angle
greater than 15 degrees.
I
NSTRUCTIONS
/T
IPPING OF THE
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

St20

Table des Matières