Télécharger Imprimer la page

Roco geoLINE Mode D'emploi page 12

Masquer les pouces Voir aussi pour geoLINE:

Publicité

Les langues disponibles

Les langues disponibles

ROCO Switching Contact
The ROCO switching contact is an operating voltage independent reed contact and can be used wherever
operating railcars are to trigger switching pulses with magnets. Small dimensions and reliable switching
functions characterize the switching contact. The glass body of the reed contact is embedded in a case of
plastic and equipped with a 30-cm long connection cable. A ROCO connection plug is attached to the end
of the connection cable. This connection plug features a protective circuit (RC section) preventing fusing
of the contact studs in the reed contact.
Warning! Do not remove this plug under any circumstances.
An unobtrusive installation is achieved by placing the ROCO switching contact into the lower part of the
GB
bedding into the provided installation cavities (Fig. 1). Additional cabling is possible with the ROCO plug
(Art. No. 10 603).
Fig. 6
Switching contact
Circuit separation
Insulating connectors can be used at the end of tracks, in order to the separate power circuits. The steel
cover plate must be removed with the stripping tool accompanying the packaging unit and replaced by
the insulating connector (Art. No. 61192), in order to be able to position the insulating connector (figs. 1
and 2).
Fig. 7
Place the stripping finger bar immediately
behind the steel cover of the track and strip
it off in the direction of the arrow, to remove
the steel cover...
The ROCO geoLINE points
All ROCO geoLINE points are equipped with a mechanical drive, with which the position of the points can
be changed by means of the adjusting lever on the side of the acclivity, in the state of delivery. The manual
drive attached with screws can be replaced with an electrical points actuator (Art. 61195), where this is
the same for both types of points.
Columns for attaching the absorbent caps and guides for the attaching spikes are found in the sub-base of
the points and installation hollows for the switch connectors are found in the arrival and departure area
of the points, apart from the attachment elements for the points actuator.
12
Connection plug with RC section
Installation cavities for the switching contact
Installed switching contact
Fig. 8
... Then place the insulating connector into the
depression in front of the end of the track and
push it onto the track.

Publicité

loading