18
Bosch Rexroth AG
NOTE!
6.11.2
Drive with frequency converter (FC)
The motor data must be entered in order to infi nitely control the transportation speed
of a drive with a frequency converter (FC).
All parameters can also be entered via the function keys on the display. An exact
description of the parameters can be found in the DCC documentation (Bosch
Rexroth IndraDrive Fc: R911 310 782).
The frequency converter can be operated with a voltage of 200-240 V or 380-480 V,
depending on the version. For further technical data, see: DCC documentation
(Bosch Rexroth IndraDrive Fc: R911 310 782).
Minimum wiring
The user must establish minimum wiring for the power supply and control unit (see
the terminal assignment plan  19). The maximum motor cable length may not
exceed 20 m. Only use shielded motor connection cables that have been approved
for the operation of frequency converters.
Malfunctions due to incorrect inputs and commissioning
The motor may be damaged or its service life shortened.
The motor data may not be changed, otherwise there is a chance that the motor
will be damaged.