INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
Kit W175-0668, Natural Gas to Propane Includes:
1
REGULATOR
1
#54 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
PILOT INJECTOR
Kit W175-0669, Natural Gas to Propane Includes:
1
REGULATOR
1
#53 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
PILOT INJECTOR
Kit W175-0670, Natural Gas to Propane Includes:
1
REGULATOR
1
#52 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
PILOT INJECTOR
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all
applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed
exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete
until the operation of the converted appliance is checked as specified in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion, shut off gas supply and disconnect electrical power.
1. Open the glass viewing door and remove the log set.
2. Remove the 2 screws from the firebox back to remove the log support (FIG. 1).
3. To remove the burner pan, remove the 4 securing screws indicated,
slide the burner pan to the left, and lift it out (FIG. 1).
4. Remove the 2 screws from the pilot bracket (FIG.2). Using a wrench,
remove the pilot tube fitting from the pilot assembly. Replace the pilot
orifice with the one supplied. Re-assemble in reverse order (FIG.3).
5. Using a deep socket wrench, remove the main burner orifice.
Replace with the orifice supplied.
6. Before repositioning the burner assembly, change the air shutter
setting according to the venturi adjustment table.
7. Reposition and re-secure the burner assembly, ensuring that the
venturi fits over the burner orifice.
8. To convert the main valve, follow the instructions that are supplied
with the regulator assembly kit. IMPORTANT: Use the screws
removed from the valve to secure.
9. The conversion data label must be filled out and attached adjacent to
the valve.
10. Turn on the gas supply and check for gas leaks by brushing soap
and water solution. Do not use open flame.
11. Replace the log set, then light the pilot and main burner to ensure that the gas lines have
been purged.
12. Close the glass viewing door. Turn on the electrical supply to the appliance.
Purge all gas lines with the glass door open.
Assure that a continuous flow is at the burner before closing the door.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
FUEL CONVERSION KIT FOR ELECTRONIC IGNITION MODELS
(C)HD35-2 / (C)HD40-2 / (C)HD46-2
These kits are for use at altitudes of 0 to 4500 feet.
(C)HD35-2
(C)HD40-2
(C)HD46-2
BURNER
ORIFICE
Kit W175-0671, Propane to Natural Gas Includes:
1
REGULATOR
1
#42 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
PILOT INJECTOR
Kit W175-0672, Propane to Natural Gas Includes:
1
REGULATOR
1
#38 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
PILOT INJECTOR
Kit W175-0673, Propane to Natural Gas Includes:
1
REGULATOR
1
#37 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
PILOT INJECTOR
FIG.2
PILOT BRACKET
SCREWS
• 1(866)820-8686
(C)HD35-2
(C)HD40-2
(C)HD46-2
FIG.1
LOG SUPPORT
SCREWS
BURNER PAN
MOUNTING
SCREWS
FIG.3
PILOT
ORIFICE
W415-1771 / 09.27.17
• www.napoleon replaces.com

Publicité

loading

Sommaire des Matières pour Napoleon HD35-2

  • Page 1 Purge all gas lines with the glass door open. Assure that a continuous flow is at the burner before closing the door. W415-1771 / 09.27.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 2 FLAME SENSOR FLAME MUST ENVELOP UPPER 3/8” (9.5mm) TO 1/2” (12.7mm) OF FLAME SENSOR HD46-2 HD46 W415-1771 / 09.27.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com 54.1B 10.3 RESTRICTING VERTICAL VENTS...
  • Page 3 Purgez toutes les conduites de gaz avec la porte vitrée ouverte. Assurez-vous que l’arrivée de gaz au brûleur est continue avant de fermer la porte. W415-1771 / 09.27.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 4 ENVELOPPER LA PARTIE HD46 HD46-2 SUPÉRIEURE DE LA SONDE DE FLAMME DE 3/8” (9,5mm) W415-1771 / 09.27.17 À 1/2” (12,7mm) Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com 54.1B 10.3 ÉTRANGLEMENTS DES ÉVENTS VERTICAUX...

Ce manuel est également adapté pour:

Hd40-2Hd46-2Chd35-2Chd40-2Chd46-2