Overview of parameter setting
Menu selection
Select:
Return to meas
Parameter setting
Viewing level
Operator level
Administrator level (All Data) adm
Return
System control
Memory card (Option)
• Record logbook
• Register recorder
• Decimal separator
• Card full
• Format
Copy configuration
Parameter sets
• Load
• Save
Function control matrix
• Input OK2
• Left softkey
• Right softkey
Time/date
Point of meas description
Release of options
Software update
Logbook
Buffer table
Factory setting
Passcode entry
34
Parameter setting
7.10 pH
23.6 °C
Activated from measuring mode: Press menu key to select menu.
Select parameter setting using arrow keys, press enter to confirm.
Administrator Level
Access to all functions, also passcode setting. Releasing or block-
[enter]
ing functions for access from the Operator level.
Operator Level
Lingua
7.10 pH
Access to all functions which have been released at the
23.6 °C
Administrator level. Blocked functions are displayed in gray and
(All Data) view
cannot be edited.
(Operation Data) opl
Viewing Level
Only display, no editing possible!
Menu only appears with SmartMedia card inserted.
Make sure that it is a memory card,
not an update card.
Commercially available SmartMedia cards must be formatted
before they can be used as memory card.
The complete configuration of an analyzer can be written on a
SmartMedia card. This allows transferring all device settings to
other devices with identical equipment (exception: options and
passcodes).
2 parameter sets (A,B) are available in the analyzer.
The currently active parameter set is read on the display.
Parameter sets contain all settings except:
Sensor type, Options, System control settings
Up to 5 parameter sets (1, 2, 3, 4, 5) are available when a
SmartMedia card (Option) is used.
Select control element for the following functions:
- Parameter set selection
- KI recorder (Start/Stop)
- Favorites menu (selected diagnostics functions)
- Unical (fully automated probe controller)
Select display format, entry
Can be called from the diagnostics menu
A TAN is required to release an Option.
Software update from SmartMedia card (update card)
Select events to be recorded
Enter own buffer set for automatic calibration
Reset all parameters to factory setting
Edit passcodes
PID 3400(X)-121