7
Cleaning & Maintenance
7.1

Cleaning the exterior of the device

Attention: Before cleaning the device with a damp cloth, disconnect
the power plug!
Clean the housing using a cloth moistened with clean water with a little mild
soap applied.
Note: Never use solvents or aggressive cleaning agents.
7.2

Cleaning the transport rollers

Deposits and residual adhesive on the transport rollers can influence the
results of the laminating process. Therefore, clean the transport rollers at
regular intervals:
1. Set the function switch to 100/125 mic.
2. Wait until the READY indicator lights up continuously.
3. Insert a piece of folded paper in the laminator infeed.
4. Repeat the process with a new piece of paper until there are no more
deposits or residual adhesive to be seen on the paper.
37
8

Troubleshooting

Problem
Diagnosis & Cause
The power plug is not
plugged into the power
socket properly.
POWER indicator
The On/Off witch is set to
does not light up
OFF.
The POWER indicator is
defective.
Laminated foil is
The laminating temperature
not completely
was too low.
transparent
The lamination foil was
inserted askew in the
laminator infeed.
Foil jam
The lamination foil is too
large.
The device no
Is the surface of the device
longer works after
hot? If so, the device's
a longer period in
overheating protection has
operation or stops
probably switched the
during operation
laminator off automatically.
Is the power plug connected
to the power socket?
The transport
rollers do not run
Is the On/Off switch is set to
ON?
If the problem cannot be solved, contact our Hotline; refer to Chapter
"Guarantee".
Solution
Connect the power plug in
the power socket properly.
Set the On/Off switch to ON.
Contact our Hotline.
Ensure that you allow the
device sufficient time to heat
up when using thicker
lamination foil.
Laminate the same foil again
to improve the lamination
result.
Refer to Chapter "Clearing
jammed lamination foil".
Refer to Chapter "Cleaning
the transport rollers".
Insert the lamination foil in
the laminator infeed straight
and with the closed side first.
Only use lamination foil of the
specified sizes, refer to
Chapter "Technical Data".
Wait for approx. 30 minutes
and try to laminate again. If
the device does not work,
contact our Hotline.
If the problem continues,
contact our Hotline.
38