Speedaire 4MU10A Manuel D'utilisation

Compresseurs d'air à deux étages
Les langues disponibles

Les langues disponibles

Liens rapides

Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Speedaire
Air Compressors
For Warranty & Service 1-888-606-5587
Do Not Return To Branch
Description
Air compressor units are intended to provide compressed air to power pneumatic
tools, operate spray guns and supply air for pneumatic valves and actuators. The
pumps supplied with these units have oil lubricated bearings. A small amount of oil
carryover is present in the compressed air stream. Applications requiring air free of
oil vapor should have the appropriate filter installed. The air compressor units are
to be mounted on a solid floor with isolation pads per the instructions provided.
Any other use of these units will void the warranty and the manufacturer will not
be responsible for problems or damages resulting from such misuse. Refer to the
enclosed "Replacement Parts Manual" to identify compressor as single stage or
two-stage.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect care-
fully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before put-
ting unit into service.
Form 5S6013
Two-Stage
®
Do not operate
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
GENERAL SAFETY INFORMATION
Since the air compressor and other
components (pump, spray guns, filters,
lubricators, hoses, etc.) used make up
a high pressure pumping system, the
following safety precautions must be
observed at all times:
1. Read all manuals included
with this product carefully.
Be thoroughly familiar
with the controls and the
proper use of the equipment.
2. Follow all local electrical and safety
codes as well as the United States
National Electrical Codes (NEC) and
Occupational Safety and Health Act
(OSHA).
Printed in U.S.A.
02433
Version 1
05/2013
4MU10A, 3VB60
Breathable Air Warning
This compressor/pump is NOT
equipped and should NOT be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, you must fit the
air compressor/pump with suitable
in-line safety and alarm equipment.
This additional equipment is
necessary to properly filter and purify
the air to meet minimal specifications
for Grade D breathing as described
in Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134, and/or
Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties are voided, and Dayton
Electric Mfg. Co. disclaims any
liability whatsoever for any loss,
personal injury or damage.
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
MANUEL
5. Wear safety glasses and
use hearing protection
when operating the
pump or unit.
6. Do not stand on or use the unit as a
handhold.
7. Before each use, inspect compressed
air system and electrical components
for signs of damage, deterioration,
IN551601AV 5/13
E
N
G
L
I
S
H
E
S
P
A
Ñ
O
L
F
R
A
N
Ç
A
I
S
Table des Matières
loading

Sommaire des Matières pour Speedaire 4MU10A

  • Page 17: Proposition 65 De Californie

    4MU10A, 3VB60 Manuel d’utilisation Veuillez lire et conserver ces instructions. Lire attentivement avant de commencer à assembler, installer, faire fonctionner ou entretenir l'appareil décrit. Protégez-vous et les autres en observant toutes les informations sur la sécurité. Négliger d'appliquer ces instructions peut résulter en des blessures corporelles et/ou en des dommages matériels ! Conserver ces instructions pour références ultérieures.
  • Page 18: Généralités Sur La Sécurité (Suite)

    4MU10A, 3VB60 Manuel d’utilisation Speedaire Speedaire Compresseurs d’Air à ® Deux Étages Généralités Sur La Sécurité et 1034 kPa pour les compresseurs à PRÉCAUTIONS DE PULVÉRISATION une étages DOIT être installée dans les (Suite) canalisations d’air ou dans le réservoir ou remplacer toutes pièces...
  • Page 19: Installation (Suite)

    Manuel d’utilisation Speedaire Modèles 4MU10A et 3VB60 Installation (Suite) Les tampons isolateurs 4C974 sont classification de pression de plus que recommandés. Ne pas trop serrer ou égal au réglage de la soupape de un endroit propre et bien ventilé. La les boulons en utilisant les tampons sûreté...
  • Page 20: Taille De Tuyau Minimum Pour Canalisation D'air Comprimé

    4MU10A, 3VB60 Manuel d’utilisation Speedaire Speedaire Compresseurs d’Air à ® Deux Étages Installation (Suite) phase). “Wiring Design and Protection.” Article 210, dans l’article “For Motors and à l’équipement. Ne jamais utiliser un 3. La taille du fil de ligne est correcte Motor Controllers,”...
  • Page 21: Fonctionnement

    Manuel d’utilisation Speedaire Modèles 4MU10A et 3VB60 mince sur le regard mais il n’y a pas Disjoncteur ou assez d’huile pour faire fonctionner le fusible sectionné Disjoncteur ou modèle. Ajouter de l’huile seulement fusible sectionné à travers du bouchon de remplissage d’huile.
  • Page 22: Manostat, Démarrage - Arrêt

    4MU10A, 3VB60 Manuel d’utilisation Speedaire Speedaire Compresseurs d’Air à ® Deux Étages Fonctionnement (Suite) dépassent cette limite. de marche. Inspecter la soupape de sûreté ASME quotidiennement (Voir Le compresseur se démarre et s’arrête permettre l’ajustage des segments de la Figure 8). Cette soupape dégage selon les réglages de manostat qui...
  • Page 23 Manuel d’utilisation Speedaire Modèles 4MU10A et 3VB60 FILTRE D’AIR COURROIES ENTREPOSAGE Mettre hors circuit Ne jamais utiliser le compresseur sans Pour l’entreposage à courte durée, et étiquetter la un filtre d’air d’admission ni avec un assuer que le compresseur soit source de puissance et dissiper toute filtre d’air d’admission obstrué.
  • Page 24 4MU10A, 3VB60 Manuel d’utilisation Speedaire Speedaire Compresseurs d’Air à ® Deux Étages Tableau de dépannage Symptôme Cause(s) possible(s) Action corrective Le moteur ronron et 1. Tension basse ou manque de tension 1. Vérifier avec un voltmètre, vérifier le relais de fonctionne lentement ou surcharge dans le démarreur magnétique ou rajuster...

Ce manuel est également adapté pour:

3vb60

Table des Matières