4.1 - Open window detection
Used to detect variations in temperature related to the opening and closing of your
windows. If you forget to switch off your appliance when a window is open for a long
time, this function lets you get around this and prevents your appliance from heating
up unnecessarily.
The appliance automatically switches to Frost Protection temperature (7°C) when it
detects an open window and rises to the setpoint temperature when it detects that
the window has been closed (the detection time is variable). The appliance reacts to
window opening and closing according to several variables, including in particular:
y
The required temperature in the room
y
The outdoor temperature
The installation's configuration
y
In the case of paired appliances, the detection on one of the appliances is passed
onto all of the paired appliances. In the same way, if the function is deactivated on
one of the appliances, it is deactivated on all of the paired appliances.
Activating/deactivating the function
This function is only accessible in PROG mode.
MENU
MODE
PROG
Detections
Programming
Settings
TURN OFF
NOTE:
Via the "Expert Menu", you may deactivate the open window detection on a single
appliance without deactivating the others in the case of paired appliances (see the
"Configurations" chapter in the expert menu on page 53). This same appliance will
switch to frost protection if an open window is detected by one of the other paired
products.

4.2 - Energy consumption

Regardless of the mode, you have access to the energy consumption indicator via the
information menu. It will display the consumption in KWh and the price in Euro.
Accessing the information menu.
Consumption
MODE
PROG
Détections
Informations
Programmation
Settings
TURN OFF
Black

4 - Advanced settings

Detections
Open wind. Disable
Informations
Consommation
Open window
Open window
The device
switches o
or
during aeration
Enable
Disable
Consommation
RAZ
63 KWh
6,36 €
No supervision
Enable
Disable
KWh price
0.150
49