at the end of the opening cycle. The
preset, adjustable automatic closing
time is automatically interrupted by the
activation of any safety system, and is
deactivated after a STOP command or
in case of power failure;
- Obstacle presence detection: When
the motor is stopped (gate is closed,
open or half-open after an emergency
stop command), the transmitter and
the control pushbutton will be
deactivated if an obstacle is detected
by one of the safety devices (for
example, the photocells);
- Hammer movement. At every opening
command, the wings press the closing
stop-ledge for a second, thus facilitat-
ing the release operation of the electric
lock connected to terminals 11-S.
It is only active if the wings are closed
and at the end of the work time or at
st
the 1
manoeuvre after the system has
been powered;
- "Operator present" function: Gate
operates only when the pushbutton is
held down (the radio remote control
system is deactivated);
- Pre-flashing. After an opening or clos-
ing command, the flasher connected to
the W-E flashes for 5 seconds before
beginning the procedure;
- Partial opening , the opening of the
second motor's door, controlled by the
TRM2 trimmer, is activated by
connecting it to the 2-3P terminals.
Select dip switch n°1 set to ON, two-
way selector;
- Pedestrian opening , the total opening
of the second motor's door is activated
by connecting it to the 2-3P terminals.
Select dip switch n°1 set to OFF, two-
way selector:
Note: if the partial or pedestrian
opening command is activated after
restoring the power supply, both doors
will open completely.
The 2-3P contact has a step-by-step
function. This function is activated
during the closing mode or when the
motor is shut down in an open position,
reversing the doors' direction. This
does not happen in the opening mode.
By pressing key 2-3P during both
doors' closing mode, they change
direction until they are fully open.
- Type of command:
-open-stop-close-stop for pushbutton
and radio transmitter;
- open-close for pushbutton and radio
transmitter;
-open only for radio transmitter.
Adjustments
- Automatic closure time;
- Partial opening time;
- Delay in closing of the M2 motor;
- Operating time.
Important! Disconnect the unit
from the main power lines before
carrying out any operation inside the
unit.
-5-

Publicité

loading

Ce manuel est également adapté pour:

Zm2