Télécharger Imprimer la page

Axis P13 Serie Guide D'installation page 15

Masquer les pouces Voir aussi pour P13 Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Function
Pin
1
0 V DC (-)
2
DC output
3–
Configurable
4
(Input or
Output)
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage
(SELV) compliant limited power source (LPS) with either a rated output
power limited to ≤100 W or a rated output current limited to ≤5 A.
Audio Connector
3.5 mm audio
connectors (stereo)
1 Tip
Audio Input
Microphone/Line in
Audio Output
Line out (mono)
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate,
or leave floating (unconnected) to deactivate.
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive load,
e.g. a relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.
AXIS P13 Series
2 Ring
15
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open
drain, 100 mA
3 Sleeve
Ground
Ground

Publicité

loading

Ce manuel est également adapté pour:

P1364P1365