3.3 Technical data
Filter data is for standard filters. Other filters may be equipped.
Table 3.1 Technical data
FlexPAK
Power
Mains voltage/frequency
Maximum flow
Flow at -15 kPa
Flow at -20 kPa
Maximum vacuum
Filter area
Weight
Inlet/outlet diameter (flanged)
Sound level
Ambient temperature range
Process air temperature
Relative humidity
Compressed air
Material recycling
Maximum installation altitude
Corrosion class according to ISO
12944-2
Supply voltage to external equip-
ment
Protection class
18
FlexPAK
18,5 kW (25 hp)
400 V±10%/50–60 Hz
3
1300 m
/h (765 cfm)
3
1000 m
/h (588 cfm)
3
800 m
/h (470 cfm)
-35 kPa (-5,1 psi)
2
6 m
(64,5 sqft)
439 kg (968 lb)
150/160 mm (7,87/6,29")
70 dB(A)
0 – +40 °C (32–104 °F)
0 – +60 °C (32–140 °F)
Max. 85%
6–10 bar (87–145 psi)
93,6% per weight
1000 m above sea level
C2 according to ISO 12944-2
24 VDC ±15%
IP42
21,5 kW (29 hp)
460 V±10%/50–60 Hz
3
1300 m
/h (765 cfm)
3
1000 m
/h (588 cfm)
3
800 m
/h (470 cfm)
-35 kPa (-5,1 psi)
2
6 m
(64,5 sqft)
439 kg (968 lb)
150/160 mm (7,87/6,29")
70 dB(A)
0 – +40 °C (32–104 °F)
0 – +60 °C (32–140 °F)
Max. 85%
6–10 bar (87–145 psi)
93,6% per weight
1000 m above sea level
C2 according to ISO 12944-2
24 VDC ±15%
IP42