Schéma De Câblage - Hayward HP50AEE Manuel D'installation Et D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. ANNEXE
6.2 Schéma de câblage :
K2
BLK WHT
Y/G
L1 L2
1
2
TO POWER
TO PUMP
SUPPLY
240V
208-230V~/60Hz
AT:Ambient temperature
COMP:Compressor
CT:Coil temperature
EP:Exhaust protection
EEV:Electronic expand valve
ET:Exhaust temperature
FM:Fan motor
FS:Flow switch
HP11:High pressure protection(4.0MPa)
HP12:High pressure protection(4.4MPa)
IT:Inlet water temperature
KM1:Contactor of high pressure
K2:Relay of pump
LP:Low pressure protection
OT:Outlet water temperature
SUT:Suction temperature
4V:4 way valve
HP50AEE/HP70AEE
HP12
KM1
K2
L2
L1
1
3
5
7
01
2
4
6
8
4V
CT
CN9
t
CN11
A13
A12
A10
A8
A6
A11
A9
A7
A5
t
t
3 4 5 6
AT
OT
t
ET
EP
RLY1
3
CN2
HP11
FS
IT
4
CN8
t
A4
A2
CN13
Controller
A3
A1
t
1
2
SUT
LP
Remote
ON/OFF
KM1
Y/G
CON2
A B GND 12V
Y/G
FM
RED BLK WHT
U
V
W
V
U
W
Y/G
COMP
20