-Fume temperature control. The temperature of the exhaust fumes is constantly controlled by
a specific feeler in order to control the regular working of the appliance, in case the
temperature is exceeding the max. value (factory value setting) a stop cycle starts, while on
the display appears "HOT EXHAUST".
-Boiler pressure control. The pressure of the boiler is constantly controlled in order to verify if
it is within the limit values (min. and max), in case the pressure is not within the requested
values a stop cycle starts, while on the display appears "PRESS WATER".
-Fume expeller motor control. The fume expeller motor is constantly controlled in order to
verify its correct working, in case of anomaly a stop cycle starts, while on the display appears
"FAN LIGHTIN".
-Control of temperatures realising feelers. The regular working of the feelers, which ensure a
correct working of the appliance, are constantly controlled by the electronic card. If the
controlled values do not re-enter into the working parameters a stop cycle starts, while on the
display appears "FEELER EXHAUST" or "FEELER WATER".

CONTROL PANEL MENU

-Push on button P3 to have access to the menu
-Use buttons P5 and P6 to run on the different menu
-Push again on button P3 to enter into the displayed menu
-Use buttons P5 and P6 to run on the different submenu, the button P1 and P2 modify the
value shown on the display
-The button P3 accedes to the displayed menu/submenu
-The button P4 returns always to the previous menu
MENU description
Menu 01 SET CLOCK (setting up the clock inside the appliance).
Menu 02 SET CHRONO (setting up the programmation for automatic switching
ON and OFF).
Menu 03 SELECT LANGUAGE (setting up the language of the control PANEL).
Menu 04 STATUS STAND-BY (activates/deactivates Stand-By modality)
Menu 05 STATUS BUZZER (setting up of buzzer sound).
Menu 06 LOAD INITIAL (continuous fuel load setting).
Menu 07 STATUS STOVE (shows the working status of the appliance).
Menu 08 PELLET CORRECT (correction of carburetion of the appliance).
Menu 9 SETTINGS TECHNIC (reserved to TECHNICIANS).
MENU 01 (clock setting)
Within this Menu you can adjust the time and the date of the electronic card, the set date and
time will be utilized as reference for the activation of the switch ON/OFF programs.