Safety Guidelines; Technical Data; Options; Assembly - resideo Brinkmann F76CS Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1

Safety Guidelines

1.
Follow the installation instructions.
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 2 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety.
2

Technical Data

2.1 F76CS/FN76CS
Media
Medium:
Connections/Sizes
Connection sizes:
Pressure values
Operating pressure range:
Operating temperatures
Operating temperature range
medium accord. to EN 1567:
Specifications
Installation position:
Note:
The filter is constructed for drinking water installations. In
case of a process water application the filter has to be
proven individually.
2.2 FK76CS/FKN76CS
Media
Medium:
Connections/Sizes
Connection sizes:
Pressure values
Operating pressure range:
Max. inlet pressure with clear
filter bowl:
Outlet pressure:
Operating temperatures
Operating temperature range
medium accord. to EN 1567:
Drinking water
3
1
/
" - 1
/
"
4
4
1.5 - 16 bar
5 °C - 30 °C
Horizontal or vertical, with
filter bowl downwards
Drinking water
3
1
/
" - 1
/
"
4
4
1.5 - 16 bar
16 bar
1.5 - 6 bar
5 °C - 30 °C
GB
Specifications
Installation position:
Note:
The filter is constructed for drinking water installations. In
case of a process water application the filter has to be
proven individually.
3

Options

For Options visit homecomfort.resideo.com/europe
4

Assembly

4.1 Installation Guidelines
Install in horizontal or vertical pipework with filter bowl
downwards
– This position ensures optimum filter efficiency
Install shut-off valves
These filters are armatures which need to be
maintained regularly
Ensure good access
– Pressure gauge can be read off easily
– Degree of contamination can be easily seen with
clear filter bowl
– Simplifies maintenance and inspection
The installation location should be protected against
frost
Fit immediately after water meter
Related to the EN 806-2 it is recommended to install
the filter immediately after the water meter
In order to avoid flooding, it is recommended to
arrange a permanent, professionally dimensioned
wastewater connection
4.2 Assembly instructions
1.
Thoroughly flush pipework
2.
Install rotatable connector piece
• Note flow direction
• Install without tension or bending stresses
When connecting to an existing flange of another make
ensure that the inlet flow is through the outer ring of
holes. If this is not so, the whole connection piece
must be installed the other way round, even if the
arrow does not then indicate the actual flow direction.
If the flange is threaded, the threaded holes must be
drilled out to a diameter of 6.3 mm.
3.
Install filter with sealing to rotatable connector
4.
Seal in pressure gauges
5.
Set outlet pressure
4.3 Discharge of reverse rinsing water
The reverse rinsing water must be routed to the drain channel
in such a way that no backwater can occur.
To do this there are 3 options:
1.
Direct connection:
4
Horizontal or vertical, with
filter bowl downwards
MU1H-1111GE23 R0220

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Braukmann fn76csBraukmann fk76csBraukmann fkn76cs

Table des Matières