Safety Guidelines; Technical Data; Options; Assembly - resideo Braukmann Triplex FF60 Instructions D'installation

Filtre à eau avec pré-filtre lavable, filtre fin et filtre à charbon actif
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1

Safety Guidelines

1.
Follow the installation instructions.
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 2 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety.
2

Technical Data

Media
Medium:
Connections/Sizes
Connection sizes:
Pressure values
Max. operating pressure:
Operating temperatures
Max. operating temperature
medium:
Specifications
Installation position:
3

Options

For Options visit homecomfort.resideo.com/europe
MU1H-1150GE23 R0220
Water
3
/
" female,
4
3
3
3
/
" male with
/
" -
/
" male
4
4
4
adapter
3
1" male with
/
" - 1" adapter
4
6 bar
45 °C
Horizontal with filter bowl
downwards
GB
4

Assembly

4.1 Installation Guidelines
Before the installation check that the hydraulic system
has been set-up according to the state-of-the-art
– If the inlet pressure exceeds the maximum
operating pressure of 6 bar, protect the product
with a pressure reducing valve
– If on outlet side the risk of hammering exists, it is
recommended to protect the filter with an anti-
water-hammer device to prevent the outlet
pressure exceeds the 6 bar
Install in horizontal pipework with filter bowl
downwards
– This position ensures optimum filter efficiency
Install shut-off valves before and after the filter
Ensure good access
– Degree of contamination can be easily seen with
clear filter bowl
– Simplifies maintenance and inspection
The installation location should be protected against
frost
Do not install in places where there is strong sunlight
In order to avoid flooding, it is recommended to
arrange a permanent, professionally dimensioned
wastewater connection
These filters are armatures which need to be
maintained regularly
4.2 Assembly instructions
1.
Thoroughly flush pipework
2.
Install filter
• Note flow direction (indicated by arrow)
• Install without tension or bending stresses
3.
The appliance is ready for use
3

Publicité

Table des Matières
loading

Table des Matières