Safety Guidelines; Technical Data; Options; Assembly - resideo HS10S Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
1

Safety Guidelines

1.
Follow the installation instructions.
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 2 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety.
2

Technical Data

Media
Medium:
Connections/Sizes
Connection sizes:
Pressure values
Operating (dynamic) pressure:
Max. inlet pressure with clear filter
bowl:
Max. inlet pressure with red
bronze filter bowl:
Outlet pressure:
Operating temperatures
Max. operating temperature
medium accord. to EN 1567:
Max. operating temperature
medium (10 bar/brass filter bowl):
Specifications
Installation position:
Note:
The filter is constructed for drinking water installations. In
case of a process water application the filter has to be
proven individually.
3

Options

For Options visit homecomfort.resideo.com/europe
4

Assembly

4.1 Installation Guidelines
Install in horizontal pipework with filter bowl
downwards
– This position ensures optimum filter efficiency
Install shut-off valve at the inlet
These filters are armatures which need to be
maintained regularly
GB
Drinking water
1
/
" - 2"
2
1.5 bar
16 bar
25 bar
1.5 - 6 bar
30 °C
70 °C
Horizontal with filter bowl
downwards
4
Ensure good access
– Pressure gauge can be read off easily
– Degree of contamination can be easily seen with
clear filter bowl
– Simplifies maintenance and inspection
Related to the EN 806-2 it is recommended to install
the filter immediately after the water meter
In order to avoid flooding, it is recommended to
arrange a permanent, professionally dimensioned
wastewater connection
4.2 Assembly instructions
CAUTION!
When connecting the solder sockets, do not solder
the sockets together with the filter. High
temperatures destroy internal parts which are
important to the function!
First solder the sockets, then insert the available
backflow preventers; only then should you install
the domestic water station.
CAUTION!
Observe the flow direction when mounting the
backflow preventer.
1.
Thoroughly flush pipework
2.
Install domestic water station
• Note flow direction
• Install without tension or bending stresses
3.
Seal in pressure gauges
4.
Set outlet pressure
4.3 Discharge of reverse rinsing water
The reverse rinsing water must be routed to the drain channel
in such a way that no backwater can occur.
To do this there are 3 options:
1.
Direct connection:
• Connector DN 50/70 as well as the necessary
pipes and siphon (3 elbows 90°) in DN 70.
2.
Discharge into floor drain
3.
Drain into open container.
Filter size
1/2" and 3/4"
1" and 1 1/4"
1 1/2" and 2"
*at 4 bar inlet pressure and 3 x 3 seconds reverse rinsing
duration
5

Start-up

5.1 Setting outlet pressure

Set outlet pressure min. 1 bar under inlet pressure.
1.
Close shut-off valve on inlet
Reverse rinsing volume*
12 litres
15 litres
18 litres
MU1H-1101GE23 R0220

Publicité

Table des Matières
loading

Table des Matières