Category 2 (usable in category 3 as well) Explosion group IIB usable in explosion group IIA
as well.
Requirements to the air supply
The pneumatic sabre saw works optimally at an operating pressure of 6 bar, measured
at the air inlet. The distance from the air supply to the machine has to be adjusted to the
application conditions on site.
We recommend installing an oiler or a maintenance unit upstream the machine for
compressed air preparation. Use acid and resin•free lubricating oil, like SAE 5W • SAE 10W, for
proper functioning of the pneumatic sabre saw. Attention! Do not use viscous oil.
Use an antifreeze lubricant, e.g.:
"Kilfrost" ,
or "Kompranol N74" in winter and if the compressed air is very moist.
The supplied compressed air has to be free of:
Foreign particles,
humidity.
Pay attention that all hoses:
Have a cross section being large enough,
do not have any restrictions or buckles,
are designed for a minimum operating pressure of 6 bar,
are replaced regularly at preventative maintenance,
have an oil resistant inner surface and an abrasion•resistant outer surface,
36