3.6.8
MENU 8 - SCAN SETUP
It is used to set the frequency scanning parameters.
Always use the knob (4) to select, modify and confirm the parameter values.
Filter
Enables the use of the "Level" parameter while scanning.
Buffer
Indicates the number of measurements for estimating the entity of the noise for each individual frequency. This
parameter influences the speed with which the noise is analyzed in real time when selecting the channels. A
greater number of samples provides a more accurate analysis, and more time will be needed to complete the
operation.
For MANUAL (menu 6) frequency selection, it is recommended to set the Buffer parameter to zero.
Increment
It indicates the increment between a scanned frequency and the next one.
A smaller increment will produce a more detailed scanning of the selected frequency interval, and more time will
be necessary to complete the operation.
Level
It indicates the threshold beyond which a detected signal will be considered noisy. The unit of measure is dB and
is an always negative value between 0 and -107dB .
Example: Level: 095 is equal to -95 dB.
Delay
This indicates the time that passes between the analysis of one sample and the analysis of the next one.
4
REMOTE SOFTWARE
Connection to a computer, via a USB connection, makes it possible to remotely view and change all configuration
parameters.
The specific "Moving D" software can be used to update the firmware both for the
well as for the MOVING D-H (hand-held) and MOVING D-B (bodypack) transmitters.
4.1
INSTALLING THE PROGRAM "Moving D"
Download program "Moving D" from internet website www.dbtechnologies.com from MOVING D downloads
section.
The program is self-installing.
4.2
CONNECTING TO THE COMPUTER
Connect a computer to the USB (15) connector located on the rear of the receiver.Start the program:
Start
Programs
4.3
UPDATING THE RECEIVER FIRMWARE
Download firmware for MOVING D-R receiver from internet website www.dbtechnologies.com from MOVING D
downloads section.
Updating the firmware does not change the device configuration.
File
Firmware Update
Follow the instructions that appear on the display until the operation is complete.
Note. Make sure to load the correct firmware on the device.
4.4
UPDATING THE HAND HELD TRANSMITTER FIRMWARE
Download firmware for hand transmitter MOVING D-H from internet website www.dbtechnologies.com from
MOVING D downloads section.
Updating the firmware does not change the device configuration.
File
Firmware Update
dBTechnologies
dBTechnologies MOVING D
Load (select the file with the RBN extension)
Load (select the file with the TEX extension)
ENGLISH
MOVING D-R receiver as
32

Publicité

loading