ENGLISH
3.2
START-UP
The receiver starts up automatically as soon as it is connected to the power supply unit.
If it has already been used previously, during start-up, the latest settings used before turning it off will be loaded.
There will then be a brief initialization procedure, after which the device is ready for use.
3.3
STAND BY
Press the "On/Stby" key for 3 seconds to put the device in stand-by, a green LED will flash to indicate this status.
To exit the stand-by status, press the button for 2 seconds, the device will be reactivated.
3.4
SHUTDOWN
To shut down the receiver, disconnect the power supply cable from the device.
3.5
FUNCTIONS ON THE DISPLAY
All receiver and system settings can be selected using the front controls (keys and knob) and are shown on the
display.
A quick list of the functions is provided in the diagram on page 34.
3.5.1
INITIAL SCREEN
20)
Reception indicator
This symbol appears when the receiver is connected to a transmitter.
21)
Battery charge indicator
Indicates the battery charge level of the transmitter connected to the receiver. If the transmitter is turned
off, the receiver continues to indicate the battery charge status at the moment it was turned off.
22)
Country indicator
Indicates the selected country and as a result the frequencies that can be used according to the current
regulations of the relative country .
23)
User name
The name of the user set on the transmitter connected to the receiver is displayed
24)
BANK indicator
The set bank is displayed.
A bank is a group of frequencies that can work at the same time. Multiple receivers that work together
must be set to the same bank.
A) Bank intermodulation order
Indicates the selectivity of the calculation for intermodulation between transmitters. The pre-calculated
intermodulation can be of the third (i3) or fifth (i5) order. The (i3) banks contain a greater number of
channels, but are less immune to intermodulation, therefore interruption of the signal, of the receivers
with respect to the (i5) banks.