The stove is clogged
early in the brazier
with burning irregular,
door glass gets dirty,
the flame is long, red-
dish and weak
Smell of smoke in the
environment. Turning
off the stove.
In the automatic posi-
tion the stove always
runs at full power
The engine smoke ex-
traction does not work
60
1. Flue with presence of stretches
too long or clogged
2. Too pellet
3. Excessive pellet or ash deposits
in the brazier
4. The brazier is not found in its
slot
5. Wind contrary to the exhaust
flow
6. Insufficient combustion air
7. You changed the type of pellets
used
8. Smoke extractor motor broken
9. Door closed incorrectly
1. Poor combustion
2. Malfunction of fan fumes
3. Installation of the flue per-
formed incorrectly
4. Clogged chimney
1. Room thermostat set to maxi-
mum
2. Significant temperature sensor
failure
3. Control panel defective or
broken
1. The stove has no voltage
2. The motor is broken
3. The board is defective
4. The control panel has failed
1. Perform periodic cleaning. See paragraph stove in-
stallation in the user manual. Check chimney cleaning
2. Decrease in the parameters the charge level of the
pellets
3. Clean the brazier after waiting for the total shut-
down of the stove
If you repeat contact your
.
Authorized Service Center
4. Check that the hole in the brazier matches the glow
plug
5. Check the chimney cap windproof and / or possibly
install it
6. Check the correct position of the brazier, its cleanli-
ness and check that the air intake in both free envi-
ronment, verify the status of the door seal, increase
the level in the parameter relative to the speed of the
fan exhaust fumes
Contact your Authorized Service
.
Center
7. Check the quality of the pellets.
thorized Service Center
8. Increase the level in the parameters relating to the
speed of the fan exhaust fumes
ally replace motor
9. Check that the glass is sealed and the seal guaran-
tees tightness
1. Contact your Authorized Service Center
2. Contact your Authorized Service Center
3. Contact your Authorized Service Center
4. Contact your Authorized Service Center
1. Reset the thermostat temperature
2. Check the operation of the sensor and replace if
necessary
3. Check the control panel and replace if necessary
1. Check the supply voltage and the protection fuse.
2. Check the motor and capacitor and replace if
necessary.
3. Replace the circuit board.
4. Replace the control panel.
Contact your Au-
Check and eventu-
.

Publicité