Failure on electrical devices
Mancata accensione
If the fl ame does not light up during the switching on or if the smokes temperature does not reach a suitable value in the
foreseen time gap, the Stove switches off and you will read the words "
on the display. Press the key "On/Off" to reset the alarm. Wait until the cooling phase is completed, clean the brazier and
start a new light-up.
Switching off while working
The Stove suddenly switches off while working (for example because it has run out of pellets in the tank or because the
motor reducer for pellets loading got broken). The Stove continues working until the pellets left in the brazier ends. You
will then read the words "
alarm. Wait until the cooling phase is completed. Clean the brazier and start a new light-up.
These alarms remind you that the brazier must be cleaned and installed correctly before switching on the
Stove.
There is no power supply
In the event of a power drop longer than one minute, the Stove can exhaust some smoke in the room: this causes no
risks. As soon as you have the power supply again, the Stove will have the words "
completing the cooling phase, the Stove will start up again automatically according to the previous settings.o precedente
all'assenza di
elettricità.
Do not attempt to start the Stove before the required time or it may get blocked.
If this occurs, switch off the switch on the back of the pellet Stove stove for 1
minute, set it on again and wait 10 minutes before starting the Stove again.
The power socket where the Stove is connected should be fi tted with "earth
connection complying with regulations in force." The Manufacturer shall not
be held responsible for damage to things or people resulting from negligent
installation.
Manual restart thermostat
Intervention in case of danger
In case of fi re, disconnect the power supply, use a fi re
extinguisher in accordance with, and if necessary, call the
fi re department and then contact an authorised qualifi ed
technical assistance
no pe l l e t
"on the display and the stove switches off. Press the key "On/Off" to reset the
N O L IGH TI N
".
B L ACK OU T
RESTART
PELLET
" on the display. After