The stove does not
turn on automatically
Lock the stove.
Pellets not being fed
into the combustion
chamber
The stove runs for a
few minutes and then
turn off
Fume extraction fan
does not stop
1. The tank is empty.
2. The resistance does not reach
the temperature
3. Resistance damaged
4. The pellet drops
5. Screw motor defective
6. The grate is not in place or is
dirty
7. Obstruction of nests or foreign
bodies in the chimney or fireplace
8. Check operation of the glow
plug
9. The ash drawer is not closed
properly
10. Clogged flue and chimney
11. Smoke extractor not working
12. Temperature sensor defective
13. Pellet wet
1. The tank is empty
2. The cochlea is no pellet
3. Technical problem of the coch-
lea
4. Reduction motor failure
5. Electronic board faulty
1. Lighting cycle not completed
2. Temporary failure of electricity
3. Probes fumes defective or bro-
ken or not inserted
1. The stove has not yet cooled
1. Fill the tank with pellets
2. Check the electrical wiring and fuses, replace if the
resistance is broken
3. Replace the resistance
4. It is recommended to unplug the power supply
before:
- check that the pellet is not caught in the chute
- check that the cochlea is not blocked by dirt
- check the seal of the pellet-door
5. Contact an authorized service center
6. Check that the hole in the brazier matches the glow
plug, clean brazier
7. Remove any foreign body from the chimney or flue
pipe
8. Make sure that there is power. Replace the spark
plug if burned
9. Close the drawer ashtray
10. Perform periodic cleaning
11. Check the operation of the extractor flue
12. Contact an authorized service center
13. Make sure the place of stowage pellet and replace
it with a handful of dry pellets
1. Load the pellets in the tank.
2. Fill the tank and proceed as instructed before igni-
tion stove
3. IT IS RECOMMENDED to unplug the power supply
before:
- empty the thank and manually free the auger from
obstructions (sawdust)
- release the slide from obstructions
- remove the dust accumulation of pellets in the bot-
tom of the tank
4. Replace the reduction motor
5. Replace the electronic board
1. Re-run power
2. Re-run power
3. Check and replace sensors
1. Allow the stove to cool. Only after cooling fan will
stop.
If the problem persists, contact your author-
ized service center
59