Low voltage control systems
* Please see instruction manuals for individual controls for proper wiring and set up of control systems.
CENTRAL CONTROLS
These control options can only be used individually
CONTROLS
ECO-Touch
• Our most complete, yet easy to use control
system
• Sleek design with backlight touchscreen LCD
• ECO mode selects the best operating mode and speed
for the season, minimizing energy use associated with
ventilation
• Set preferred indoor relative humidity range and ventilation
mode for day and night conditions
• No battery to replace, all programmed settings are
retained during power outage
• Maintenance reminder indicator
• Error code messages reduce troubleshooting time
• MODE button provides 3 modes of operations: Ventila-
EDF7
tion , Recirculation and Standby
• User selected fan speed: Reduced, Medium, Normal
and 20 minutes per hour
• AUTO setting allows the homeowner to deactivate the
dehumidistat
• When the humidity exceeds the desired setpoint, the
ventilation system operates at Normal speed.
• Once the desired humidity level is achieved, you ventila-
tion system resumes to its previous mode of operation
EDF1
• Press button once for continuous LOW speed
• Press button twice and the unit will cycle 20 minutes
ON/ 40 minutes OFF and repeat
• Press button a third time and the system will run
continuously on HIGH speed
AUXILIARy CONTROL – These controls can be paired
• 20- minute timer with LED light
RTS2*
• Boosts system to high speed with the touch of a button
• Up to 5 can be used in one system
• Use in bathroom, kitchen, laundry room
• Press button once and unit will operate in continuous
RTS3
mode on HIGH speed for 20 minutes (Green).
• Press button a second time and unit will operate
in continuous mode on HIGH speed for 40 minutes
(Yellow).
• Press button a third time and unit will operate in
continuous mode on HIGH speed for 60 minutes (Red).
• Press button a fourth time to cancel the timer (LED
turns off).
• Rotary dial Dehumidistat
MDEH1
• Multiple units can be used
• We recommend setting the relative humidity above
80% during the summer
fantech
FEATURES
CONNECT TO
EDF
EDF
EDF
EDF
EDF
EDF
+T
-T
D
D
COM
D
D
To avoid window
condensation:
• It is not necessary to
change the humidity
control every day. Monitor
the average weekly
temperature or
experiment with various
settings until you find a
level that is comfortable
for you. Adjust the
control when needed.
A dehumidistat is ideal
for use in energy
efficient houses where
indoor humidity (during
the heating season) is
higher than outdoor
levels. High humidity is a
major cause of structure
damage and IAQ
problems such as mold
and mildew.
*Maintain polarity
between control
and HRV
(+ → + ; - → -)