Bloom 400 Greenhouse Heater
servicing. Refer to leak check instructions within
installation section of this manual.
11. This heater should be inspected for proper
operation by a qualifi ed service person before
each use and at least annually.
12. Always turn off the gas supply to the heater if the
heater is not going to be used.
13. This heater is wired for 230/60/1 electrical sup-
ply. There are two hot leads, a neutral lead, and
a ground lead. The heater must be connected
to a properly grounded electrical supply. Failure
to use a properly grounded electrical supply can
result in electrical shock, injury, or death.
14. If gas fl ow is interrupted and fl ame goes out, do
not relight the heater until you are sure that all
gas that may have accummulated has cleared
away. In any event, do not relight the heater for
at least 5 minutes.
15. When the heater is to be stored indoors, the
connection between the propane gas supply
container and the heater must be disconnected.
All containers must be stored in accordance
with the Standard for the Storage and Handling
of Liquefi ed Petroleum Gases, ANSI/NFPA 58,
or CSA B149.1, Natural Gas and Propane Gas
Installation Code.
16. Propane gas supply containers have left handed
threads. Always use the appropriate wrench
to make a connection to tighten or loosen the
P.O.L. fi tting at the cylinders' gas supply valve.
17. Not for use with ductwork. DO NOT attach
any ducts to the heater's air inlet or hot air
discharge.
Owner's Manual • Bloom 400
18. The gas supply system must be pressure tested
prior to heater start-up. When testing, ensure the
following are adhered to:
a. The appliance and its individual shut off must be
disconnected from the gas piping system at test
pressures in excess of 1/2 PSI (3.5 kPa)
b. The appliance must be isolated from the gas
supply by closing its individual shut-off valve
during any pressure testing of the gas supply
system at test pressures equal to or less than 1/2
PSI (3.5 kPa)
19. Do not operate the heater with any panel removed.