contains a motor protection filter. Mul-
tipacks contain four motor protection
filters (available depending on country).
 Open the dust compartment lid.
 Pull the dustbag out by the grip on
the collar.
 Lift up the filter frame until it clicks
and remove the old filter. Hold by the
clean, unsoiled section to remove it.
 Replace with a new motor protection
filter.
 Close the filter frame.
 Fit the dustbag into the holder as far
as it will go.
 Close the dust compartment lid se-
curely, making sure it clicks into posi-
tion. Take care not to trap the dust-
bag when doing so.

Replacing the exhaust filter

Depending on the model, your vacuum
cleaner will be fitted as standard with
one of the following exhaust filters (dia.
06):
a AirClean
Replace this filter every time you start a
new packet of Miele dustbags. Every
packet of original Miele dustbags con-
tains one AirClean exhaust filter. Mul-
tipacks contain 4 AirClean filters (avail-
able depending on country).
b AirClean Plus 50 (light blue)
Replace this filter after approx. one
year. Make a note of the date on the fil-
ter.
c Silence AirClean 50 (grey)
d Active AirClean 50 (black)
e HEPA AirClean 50 (white)
44
Replace these filters when the
timestrip® filter change indicator is
completely red (dia. 11). The indicator
lights up after approximately 50 hours
of operation, which is equivalent to
about a year of average use. You can
continue vacuuming when the light
comes on. However, the suction power
will be reduced as will the effectiveness
of the filter if it is not replaced in good
time.
Replacing the AirClean
filter (dia. 32 + 33)
Do not use more than one exhaust fil-
ter at a time.
 Open the dust compartment lid.
 Press the release catch on the filter
grille and open the grille until it clicks.
 Grasp the used AirClean filter by one
of the clean, unsoiled sections and
take it out.
 Replace it with a new AirClean ex-
haust filter.
If you wish to fit an AirClean Plus 50,
Silence AirClean 50, Active AirClean
50 or HEPA AirClean 50 filter, see the
"Replacing one type of exhaust filter
with another" section.
 Close the filter grille.
 Close the dust compartment lid.
Replacing the AirClean Plus 50,
Silence AirClean 50, Active AirClean
50 and HEPA AirClean 50 exhaust fil-
ters (dia. 34 + 35)
Do not use more than one exhaust fil-
ter at a time.