a. saFety instructiOns
Install this device only when it complies with local/national legislation, by-laws and
standards.
This product is intended to be used for room heating in residential houses and is
only suitable for use in dry locations in normal household situations, indoors in liv-
ing room, kitchen and garage. Do not install the stove in bedrooms or bathrooms.
Correct installation of this stove is extremely important for product performance
and your personal safety. Therefore:
• T his heater must be installed by a by Tectro authorized heating and installation
engineer. The warranty can only be effective when it is installed by a by Tectro
agreed professional. The instructions for use given in this manual may vary
from local and/or regional legislation. When this is the case the most stringent
condition is applicable. Any responsibility in cases of installation not comply-
ing to local legislation and regulation and/or in case of incorrect air ventila-
tion and/or inappropriate use is explicitly declined by the manufacturer and
distributor.
• T he stove must only be installed in a room where the location, the building
construction and the use of the room do not interfere with safe operation of
the stove.
Always contact your dealer or installer immediately in case you experience problems
with your stove or when you have difficulty reading or understanding this manual.
Burning pellets needs oxygen, thus air. Ensure to allow sufficient fresh air to enter
the room. Per hour an additional 50 m
requirement for the room. Always have a fresh air inlet to the room with a section
of at least a quarter of the section of the exhaust flue, with a minimum of 100 cm
It might be necessary to shut off mechanical ventilation, laundry drying machine
and/or kitchen extraction hoods as this might negatively influence the draught
needed for the stove.
• U se proper equipment to transport the stove. Using not adequate equipment
might lead to personal injuries and/or damage to the stove.
• D o not place any inflammable objects and/or materials within 200 mm. of the
sides and back of the stove and not within 800 mm to the front of the stove.
• T he stove is designed for free standing and is not suitable for build-in. Keep
200 mm clearance between walls and side/back of the stove. (See picture 1)
• W hen the floor is made of inflammable material, place the stove on a fire
proof base plate. The covered area by the fire proof base plate needs to be 400
mm. larger to the front of the unit and needs to be 200 mm. larger measured
from the sides of the unit (see picture 1, dimensions D and E)
• I n case the walls are made out of inflammable materials make sure to have
sufficient distance from side/back of stove to the wall. Make sure that even
air is needed above the normal ventilation