Tectro TBH 460 Manuel D'utilisation page 107

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
man_TBH460 ('11).indd 107
Wood pellets do not
The tank is empty
get to burning pot box
Auger is blocked
No electrical input to
the stove
Auger motor is dama-
ged
Verify if there is an
alarm activated on
display
The fire goes out and
The tank is empty
the stove stops.
Auger is blocked
Wood pellets are not
good quality.
The phase 1 parameter
set in the circuit board
is too low.
The fire goes out and
Verify if there is an
the stove stops.
alarm activated on
display
The fire has a weak
Not enough combusti-
and orange flame,
on air reaches the fire
pellet do not burn
correctly and/or the
glass turns black (too)
quickly
The exhaust/flue gas
pipe/chimney is bloc-
ked
Fill the pellet hopper.
Unplug the stove from electricity, move
the inside hand protection of the tank
away, empty the tank, carefully clean
the visible parts of the auger. Replace
the hand protection and start again.
Call authorized Tectro technician if the
problem still continuous.
Verify if the plug is connected
Replace the motor, Code COM0232. By
authorized Tectro technician only
See relative paragraph in this chapter.
Fill the tank.
Unplug the stove from electricity,
move the inside hand protection
of the tank away, empty the tank,
carefully clean the visible parts of the
auger. Replace the hand protection
and start again. Call authorized Tectro
technician if the problem still continu
Try better quality wood pellets.
The wood pellets supply to the bur-
ning pot might need adjustment. By
authorized Tectro technician only
See relative paragraph in this chapter.
Check the following (by end-user):
Possible obstructions of the combus-
tion air inlet tube on the back of the
stove (see picture 6 in chapter D.7.)
clean the fresh air inlet tube.
Burning pot grid holes obstructed
and/or burning pot box with too
much ash and/or burning pot too dirty
and must be cleaned, see chapter F.3.5
By authorized Tectro technician only:
exchanger pipes inside the stove too
dirty; clean the extractor blades and
its scroll.
Have exhaust/flue gas pipe / chim-
ney cleaned by authorized chimney
sweeper immediately. Call authorized
chimney sweeper.
4
1
107
07-10-11 09:06

Publicité

Table des Matières
loading

Table des Matières