Tectro TBH 460 Manuel D'utilisation page 110

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
1
4
110
man_TBH460 ('11).indd 110
Stove switches off.
Stove is overheated
Alarm displayed is
"AlAr Sec"
Stove switches off,
Fumes outlet tempera-
Alarm displayed is
ture sensor is broken
"AlAr HottEmp"
Electronic circuit board
is broken
The room air recircula-
tion fan is broken
Too high parameter
set
Stove switches off.
Fumes outlet tempe-
Alarm displayed is
rature sensor discon-
"AlAr Sond"
nected
Fumes outlet tempera-
ture sensor is broken
Stove is in steady con-
The burning pot needs
dition. Display shows
cleaning
"Stop FirE
Stove is in steady con-
Cold start whem room
dition. Display shows
air temperature is be-
"Stop FirE
low 12°C. Ignitor can
not reach the desired
temperature
Display shows "ont"
Room temperature
below 0°C
Reset the stove by manual reset but-
ton at back of the stove. Possible
cause: too high room temperature.
Open doors to other rooms. If the
problem continues call authorized
Tectro technician
Replace the sensor, Code COM0239.
By authorized Tectro technician only
Replace the electronic circuit board.
Code COM0231.Call a specialised
technician
Replace the fan, code COM0268. By
authorized Tectro technician only
Change relative parameter. By autho-
rized Tectro technician only
Verify the sensor is connected to the
circuit board card By authorized Tec-
tro technician only
Replace the sensor, Code COM0239.
By authorized Tectro technician only
Stove works at minimum rate. Smoke
gas extraction fan works at maxi-
mum rate, no direct problem. Clean
burning put as soon as possible (see
chapter F.3.5)
Use BBQ fire lighter sticks to ignite
the fire. Continue with restart the
stove when the fire lighter sticks are
burning. Follow the normal proce-
dure.
Not an error. The thermometer is not
able to measure and display negative
temperatures.
07-10-11 09:06

Publicité

Table des Matières
loading

Table des Matières