5.2 Charging of the Electric Vehicle
First the grid connector has to be connected to the power supply socket.
Subsequently the charging electronics is then initialized. This process can be identified by an
oscillating flashlight signal. Then the allocated LED of the current which has been adjusted the last
time, is illuminated.
Now the intended charging current has to be adjusted via the selection button.
CAUTION! For the selection all of the following points have to be considered.:
a) Maximum current according to the feed cable of the electric installation NRGkick is connected to
b) Maximum current according to the used grid connector
c) If an adapter is used: Maximum current, which the adapter is approved for
Points a) and b) are also valid if an adapter is used
Plug the vehicle connector to the vehicle.
After the connected vehicle is detected by the charging device, all LED lights are on for a short time.
From that time the charging current cannot be changed any more via the selection button of the
charging unit.
Remark: If – contrary to the correct plugging sequence – the car is already connected before the
grid connector is plug in, approximately 10s are remaining for the adjustment of the charging
EN
power. After an adjustment is made, you have 4 seconds time for another adjustment after
releasing the selection button. A short flash up of all LEDs indicates that your vehicle has been
identified. From that moment the charging current cannot be changed any longer via the selection
button of the charging unit.
Finally the charging device is operating in the mode "vehicle charging". Depending on the vehicle
type, the charging process will start after a few seconds.
5.3 Interruption of the charging process via the charging unit
If the selection button is pressed for 4 seconds the charging process will be interrupted and the
charging unit will re-initialize. Subsequently you have again the possibility to change the charging
power. This function is only available during the first 2 minutes after starting the charging
procedure.
Remark: After the initialization 25 seconds remain for another adjustment. Then the charging
device switches back to the "vehicle charging" mode.
5.4 Interruption of the charging process
Generally the charging process is interrupted via the vehicle. Follow the instruction manual of your
vehicle. After that the vehicle connector is unlocked and can be unplugged. Finally disconnect the
grid connector of the charging device.
Ver.:1512-03