Technical Data; General Precautions; Installation Regulations - Nordica PADOVA Instructions Pour L'installation, L'utilisation Et L'entretien

Cuisinière à bois
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PADOVA

1. TECHNICAL DATA

Definition in accordance with
Constructive system
Nominal power in kW
Efficiency in %
Assorbimento elettrico in W
Smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H
Hourly wood consumption in kg / h
CO measured at 13% oxygen in %
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Outer air inlet Ø in mm (minimum surface cm
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
heatable m
(30 kcal/h x m
3
For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume
(# #)
of the product is: favourable type of building (30 kcal/h x m
building (50 kcal/h x m
3
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,
in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.

2. GENERAL PRECAUTIONS

La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibility
of the system as a whole. La NORDICA S.p.A. declines any responsibility for the product that has been modified without written
authorisation as well as for the use of non-original spare parts.
This appliance is not suitable for the use of inexperienced people (included children) or with physical, sensorial and mental reduced
capacities. They have to be controlled and educated in the use of the appliance from a responsible person for their security. The children
have to be controlled to be sure that they would not play with the appliance. (EN 60335-2-102/7.12).
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproof
rules.
NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. La NORDICA S.p.A. cannot be held responsible for lack of
respect for such precautions.

3. INSTALLATION REGULATIONS

Installation of the Product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations
and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,
being national, regional, provincial or town council present in the country within which the appliance is installed, besides these present
instructions.
Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and will
assume full responsibility for final installation and as a consequence the correct functioning of the installed product.
The Product, assembled and ready for the installation, must be connected with a junction to the existing flue of the house. The junction
must be possibly short, straight, horizontal or positioned a little uphill. The connections must be tight.
Before installing the appliance, carry out the following checks:
• UPPER smoke output - REAR - LATERAL
7096302
O)
2
(wood with 20% humidity)
)
2
)
(# #)
3
).
); less favourable type of building (40 kcal/h x m
3
PADOVA
EN 12815
1
8
25
75
150
4 - 200 x 200 Ø 200
12 ( 1,2 mm H
O)
2
2,5
0,07 - 875 mg/m
3
10,5
270
100 ( 100 cm
)
2
210 x 175
226 x 270 x 384
310 x 286 x 410
Movable - flat
850-910
900
600
174
Chapter FIRE SAFETY
229
); unfavourable type of
3
17

Publicité

Table des Matières
loading

Table des Matières