USER U/I menu,
user charging
settings
(continued)
IMPORTANT! the conservation charging voltage is only available in Charge mode.
Conservation charging does not take place if conservation charging is set to OFF.
However, if the battery voltage drops below 12 V, charging starts.
IMPORTANT! if charging does not end automatically after the set time has elapsed, the
charger will be switched off as a safety precaution.
USER U/I menu,
„flash operation"
settings
Set main charging voltage (setting range: 12.0 - 15.5 V)
-
Press Start/Stop button
-
Display flashes. Adjust main charging voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
Set safety cut-out (setting range: 2 h - 30 h)
-
Press Start/Stop button
-
Display flashes. Adjust time in 10 min intervals
-
Press Start/Stop button to confirm setting
Set the maximum current for „flash operation" (Setting range: see Technical Data)
-
Press Start/Stop button
-
Adjust „flash operation" current in 0.5 A steps
-
Press Start/Stop button to confirm setting
Set the „flash operation" voltage (setting range: 12.0 - 15.5 V)
-
Press Start/Stop button
-
Adjust „flash operation" voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting