Télécharger Imprimer la page

BFT EOS 1200 U Instructions D'utilisation page 33

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
during the manoeuvre.
• Check the manual opening control operation.
• Check the opening and closing operations using the control devices fitted.
• Check the normal and customised operation electronic logics.
11) AUTOMATION DEVICE USE
- Since the automation device can be remotely controlled by means of a radio
control device or a Start button, and therefore when not in sight, all the safety
devices must be frequently checked in order to ensure their perfect efficiency.
In the event of any malfunction, request immediate assistance from qualified
personnel. Children must be kept at a safe distance from the automation opera-
tion area.
- Partial or pedestrian opening is to be treated as an operation to be performed
only occasionally and no more than 5 such operations should be performed in
a row if the automated system is to work properly.
12) AUTOMATION CONTROL
The use of this control device allows the gate to be opened and closed automati-
cally. There are different types of controls (manual, radio control, magnetic card
access etc.) depending on the installation requirements and characteristics. For
the various control systems, see the relevant instructions. The automation device
users must be instructed on control and operation.
13) ACCESSORIES
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
1
180 
TCA
CL. D IST.
7
 100
SLOUD
PARTIAL
00,1
06,0
OPEN
99 
OP. F ORCE
99 
CLS. F ORCE
 40
99 
OP SPEED
 40
 99
CL SPEED
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
INSTALLATION MANUAL
Default
Personal
Definition
Automatic clos-
40
ing time [s]
Slow-down
distance
[cm]
Partial opening
01,0
[m]
Leaf force
during opening
 75
[%]
Leaf force
during closing
 75
[%]
Opening speed
 99
[%}
Closing speed
 99
[%]
SM1
External release device to be applied to the cremone bolt already fitted
to the overhead door (fig.22).
SET/S External release device with retracting handle for sectional doors mea-
suring max 50mm (fig.23).
ST
Automatic bolt release device for spring-operated overhead doors. Fitted
to the control arm, it automatically releases the side door bolts (fig.24).
14) MAINTENANCE
Before carrying out any maintenance operation, disconnect the system power
supply.
• Periodically check the tension of the chain/belt (twice a year).
• Occasionally clean the photocell optical elements, if installed.
• Have a qualified technician (installer) check the correct setting of the electronic
clutch.
• When any operational malfunction if found, and not resolved, disconnect
the system power supply and request the assistance of a qualified technician
(installer). When the product is out of service, activate the manual release
device to allow the door to be opened and closed manually.
If the power supply cable is damaged, it must be replaced directly by our
company or our technical service department or by a technician having
similar qualification so as to avoid any risks.
14.1) FUSE REPLACEMENT (Fig.25)
WARNING! Disconnect the mains voltage.
Remove the rubber protection from the fuse-carrier. Remove the fuse (Fig.25,
Ref.A) to be replaced and replace it with a new one. After completing this opera-
tion, re-fit the rubber protection.
Waiting time before automatic closing.
Motor slow-down distance during opening and closing, expressed in cm
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance following activation of PED pedestrian command. Set the numerical value
of partial opening in the range 10 cm (00,1) to 6 m (06,0)
Force exerted by leaf during opening. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
Force exerted by leaf during closing. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
Percentage of maximum speed that can be reached by motor during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Percentage of maximum speed that can be reached by motor during closing.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Description
EOS 1200 U
- 33

Publicité

loading