7. COMMISSIONING

ATTENTION!: Check that the equipment has
been connected to the ground wire.
ATTENTION!: Check that the line voltage is that
indicated on the equipment rating plate.
Proceed with the following operations for commissioning:
• Fill the tank completely via the inlet faucet and check that
there are no water leaks from gaskets and connections.
• Do not exceed the max. permissible pressure indicated in the
"general technical data" section.
• Check the water circuit safety devices.
• Plug the unit into the power outlet.
• When the plug is inserted, the boiler is in standby mode, the
display remains off, the power button lights up.
• Press the On button, the unit is activated in "ECO" mode (fac-
tory setting).
In case of a sudden power outage, when restored the equip-
ment will restart from the operating mode prior to the interrup-
tion.

7.1 Query, editing operating parameters

This equipment has two distinct menus, respectively, for con-
sulting and editing the operating parameters (see "7.1.1 List of
equipment parameters").
With the equipment operating, the parameters can be freely
consulted at any time by unlocking the buttons (see "6.1 Turn-
ing the water heater on and off and unlocking the buttons") and
pressing the "
" and "+" buttons together for 3 seconds. The
label of the first parameter is shown on the display with the letter
"A". Pressing the "+" button displays its value and, pressing this
button again, the label of the second parameter "B" is displayed,
and so on.
The entire parameter list can then be scrolled forward/back with
the "+" and "-" buttons.
Press the "ON/OFF" button to exit.
Editing one or more operating parameters can only be done
with the equipment in standby mode and requires the password
to be entered.
NB!: "Use of the password is reserved for qualified per-
sonnel; any consequences due to incorrect parameter
settings will be the sole responsibility of the customer.
Therefore, any interventions requested by the customer
from an authorized technical assistance center FERROLI
during the standard warranty period, for product prob-
lems due to incorrect settings of password-protected pa-
rameters, will not be covered by the standard warranty.".
96
EN
EGEA
200 LT-S - 260 LT-S - 200 LT - 260 LT
With buttons unlocked, only in standby mode, press the "
and "+" buttons together for 3 seconds to access the equipment
parameter editing menu (password protected: 35). The display
shows the two digits "00". Press the "
on the left flashes and with "+" and "-" select the first number to
enter (3) and press "
for the second digit (5).
If the password is correct, the parameter P1 is displayed. Press-
ing the "+" button displays the default value of this parameter
which can be changed by pressing
"-" buttons it is possible to change the value within the permis-
sible range for this parameter. Then press
the "+" button to continue with the other parameters.
After editing the desired parameters, press the on/off button to
save and exit.
The equipment now returns to standby mode.
cod. 3541T600 - Rev. 04 - 05/2020
" button. The digit "0"
" to confirm. Proceed in the same way
, and using the "+" and
to confirm and
"