Air supply
The amount of combustion air for Jøtul's products is approximately
25-40 m 3 /h. The outside air connection may be fitted directly to the
Jøtul F 470 SHD through:
The base/pedestal/leg or
through a flexible supply hose from the outside/chimney
(only if the chimney has its own duct for external air) and to
the product's outside air connector.
Fig. 2A, through an outside wall
Fig. 2B, through the floor and ground plate
Fig. 2C, through the floor and basement
Fig. 2D, indirectly through an outside wall
8

4.0 Installation

NB: Check that the fireplace is undamaged before installation
begins.
NB: The product is heavy! Ensure you have help when positioning
and installing it. Make sure the product does not topple over.
NB: Read the Installation and Operating instructions carefully
before installing the fireplace!
4.1 Prior to installation
The standard product comes in three or more consignments
One with the fireplace itself, one with the base, pedestal or leg
and side panels.
You will need the following tools to install the product: Spirit
level, ratchet with 10 mm and 13 mm sockets and hex keys with
5 mm socket.
Fig. 3
1. Remove the packaging (cardboard and wooden frame) and
spread the cardboard out on the floor behind the fireplace.
2. Leave the stove standing on the transport pallet.
3. Remove the top plate (Fig. 3 A) with the top grate (Fig. 3 B).
4. Remove the gloves and bowl from the ash pan. Place the
bowl on the top grate right up to the end if the flue pipe is
rear-mounted.
5. Check that the control handles (Fig. 3 C) move freely.