Alarms
Display
Fixed alarm LED
Flashing word "Lev"
I.e.
Man
Lev
P100%
Fixed alarm LED
Flashing words "Lev" and "stop"
I.e.
Man
Lev Stop
P100%
Fixed alarm LED
Flashing word "Flw"
Man
F
I.e.
Flw
P100%
I.e.
Parameter Error
to default
Flashing word "OFA"
Flashing word "stop"
I.e.
High
475 mV OFA
Stop
P 75%
Flashing word "Alm"
I.e.
High
475 mV Alm
P 75%
Flashing word "Cal"
I.e.
High
475 mV Cal
P 75%
EM00136162
End
of
interrupting pump operation
End of level alarm, with interruption
to pump operation
Active flow alarm. The pump has
not
received
number of signals from the flow
sensor.
Communication
eeprom.
PROG
O.F.A. alarm
The probe reading is outside the set
alarm band range
Probe not calibrated alarm
Cause
level
alarm,
without
the
programmed
error
with
the
rev 1.1
Interruption
Restore the liquid level.
Restore the liquid level.
Press the
key
Press the
key to restore
the default parameters.
Press the
key to stop the
flashing word "stop". Press the key
again to start up the pump again.
Make sure that the "Alarm Band"
parameter is set correctly in the
programme
Calibrate the probe
10