Athena AT BT Série Manuel D'installation page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Paragraph 4 – Setting the Maximum Flow
Programming
PROG
Pump Functions
-
Max flow rate
Max flow rate
P100%
P100%
-
Max flow rate
F320s/m
Paragraph 5 – Setting the Alarm Relay
Programming
PROG
Pump Functions
-
Max flow rate
P100%
-
Alarm Relay
N.Open
-
Paragraph 6 – Flow rate Calibration
Programming
PROG
-
-
Pump Calibration
0,23 cc/stroke
Pump Calibration
Manual
-
Pump Calibration
Automatic
-
EM00136160
-
+
-
-
+
-
-
+
-
-
Pump Calibration
+
cc/stroke
0,23
Automatic Cal.
Start 100 strok.
Automatic Cal.
Strokes
100
-
Automatic Cal.
+
ml
20
This makes it possible to set the maximum flow offered by
the pump, and the programmed mode (% or frequency) is
used as the standard unit of measurement when displaying
the flow. Changes can be made by pressing the
key, then using the
Press
to confirm and return to the main menu
This is used to set the alarm relay in the absence of an
alarm situation, if open (default) or closed.
Changes can be made by pressing the
using the
keys to set the new value. Press
to confirm and return to the main menu
The memorised cc value per strike appears in the main
menu. It can be calibrated in two different ways:
MANUAL – manually enter the cc value per strike using the
keys and confirm by pressing the
AUTOMATIC – the pump makes 100 strikes, which are
started by pressing the
process, enter the quantity sucked up by the pump using the
keys and confirm by pressing the
The entered figure will be used in flow calculations.
rev. 1.1
Operation
keys to set the new value.
Operation
Operation
key. At the end of this
key, then
key
key.
7