Use And Care; Operation - Garland HEEGM XX CL Manuel D'installation Et D'utilisation

Table des Matières

Publicité

INSTALLATION Continued
FOR HEEGM24 & 36 SIZE UNITS
• Connect a manometer to the test spigot on the
manifold.
• Turn on the unit and adjust the burners so that they are
all set to high.
• If necessary, adjust the pressure so that the reading
on the manometer matches the pressure value stated
on the rating plate. To adjust the pressure, access and
rotate the pressure adjustment screw on the regulator
installed at the appliance.
FOR HEEGM48 & 60 SIZE UNITS
• Connect a manometer to the test spigot on the LEFT
manifold.

USE AND CARE

Operation

IF FOR ANY REASON YOU SMELL GAS, BEFORE, DURING OR
AFTER OPERATION, TURN THE POWER OFF AND CLOSE THE
MANUAL SHUT-OFF VALVE TO THE APPLIANCE. CONTACT
AN AUTHORIZED SERVICE AGENT FOR SERVICE BEFORE
ATTEMPTING TO RESTORE GAS SUPPLY. FOR A LIST OF
AUTHORIZED SERVICE AGENTS, REFER TO THE GARLAND WEB
SITE AT http://www.garland-group.com
1. To turn on and use this appliance, the operator simply
needs to turn on the power switch(es).
FOR STANDARD 120 VOLT UNITS:
2. Models HEEGM-24CL and HEEGM-36CL have one power
switch on the lower right side of the unit. Once pushed
to the "ON" position, gas is supplied to all the burners. At
the same time a spark is supplied to each burner to ignite
the gas. Sparking will continue until a flame has been
established at all burners.
Part # 4530868 (04/25/12)
• Turn on the LEFT side of the unit only (by activating the
left switch) and adjust the burners so that they are all
set to high.
• If necessary, adjust the pressure so that the reading
on the manometer matches the pressure value stated
on the rating plate. To adjust the pressure, access and
rotate the pressure adjustment screw on the regulator
installed at the appliance.
6. Inspect the flame of each burner to determine whether
adjustments to the burner air shutter are necessary.
Adjustments are made by loosening the air shutter screw;
rotating the shutter and re-tightening the screw. If the
tips of the flame appear too yellow, the shutter should be
turned to allow MORE air to enter the burner cavity. If the
flames appear to be lifting off the burner ports, the shutter
should be turned to allow LESS air to enter the burner
cavity.
3. Models HEEGM-48CL and HEEGM-60CL have two power
switches on the lower right side of the unit. Once pushed
to the "ON" position, they operate in the same manner as
the single switch above, except they allow the operator to
run the left and right side of the broiler independently as
shown below:
• HEEGM-48CL: The left switch operates burners 1 to 4
on the left side of the unit. The right switch operates
burners 5 to 9 on the right side of the unit. The entire
unit runs when both switches are used.
• HEEGM-60CL: The left switch operates burners 1 to 6
on the left side of the unit. The right switch operates
burners 7 to 11 on the right side of the unit. The entire
unit runs when both switches are used.
FOR OPTIONAL 220-240 VOLT UNITS, THE MAIN
POWER SWITCH NEEDS TO BE TURNED ON BEFORE
THE FUNCTIONALITY OF THE SWITCHES DESCRIBED IN
2 & 3 APPLY. REFER TO IMAGES BELOW FOR A VISUAL
COMPARISON BETWEEN THE STANDARD 120 AND OPTIONAL
220-240V MODELS.
Page 9

Publicité

Table des Matières
loading

Table des Matières