Phoenix Mecano RK ROSE+KRIEGER Powerlift M Memory Notice D'assemblage page 384

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Type/Model
classic
ave
Footprint
/w
/
technic
(LxW)
Height
Lift
Weight
Supply voltage (primary)
Control board
Type of protection
External electrical connection
Lifting speed
Integrated transformer rating
(only for Start/Stop)
Duty cycle
Permanent noise level
max. current drain (primary)
max. current drain (external)
max. power consumption
Primary fuse
(not with external)
Ambient temperature
max. compressive/tensile force
Torque loading (static)
200 x 160 mm/208 x 168 mm/200 x 170 mm (L x W)
Start-Stop (not with external)
With entire surface and cover without drilled holes, the stand and
application surfaces achieve the protection class IP 30. Installation of the
RK SyncFlex adapter plates achieve the protection class IP 20.
max. 10-25 mm/s (see maker's plate)
(1.5 minutes operation/8.5 minutes pause)
1.0 A (230V AC) 2.0 (115V AC)
1.6 A/T (230V AC) 3.25 A/T (115V AC)
1000-3000 N (see maker's plate)
6. Product information
RK
spindle
Powerlift
648 mm
500 mm
19 kg
24V-230V AC 50/60 Hz
DIN plug, 8-pin
75 VA
15% for 10 minutes
< 60 dB (A)
3.5 A at V=24V DC
120 W
+5 °C to +40 °C
Max. 125 Nm
39

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rk rose+krieger memory synchro

Table des Matières