6.2 Technical specification
Type/Model
wave
Floor plan
(LxW)
Height
Lift
Weight
Supply voltage (primary)
Control board
Type of protection
External electrical connection
Lifting speed
Integrated transformer rating
(only for Start/Stop)
Duty cycle
Permanent noise level
max. current drain (primary)
Start-Stop
max. current drain (external)
max. power consumption
Primary protection
Ambient temperature
max. compressive/tensile force
Torque loading (dynamic)
Bracing moment (static)
Start-Stop (not with external)
With entire surface and cover without drilled holes, the stand and
application surfaces achieve the protection class IP 30. Installation of the
RK SyncFlex adapter plates achieve the protection class IP 20.
15 mm/s
(1.5 minutes operation/8.5 minutes pause)
1600 N/800 N
6. Product information
RK
telescopic
Powerlift
212 x 172 mm
560 mm
650 mm
16 kg
24V-230V AC 50/60 Hz
DIN plug, 8-pin
120 VA
15% for 10 minutes
< 60 dB (A)
0.8A (230V AC)
3.5 A at V=24V DC
180 W
1.0A/T (230V AC)
+5 °C to +40 °C
Max. 125 Nm
Max. 250 Nm
30 mm/s
800 N/800 N
37